Baxi Eco blue...A odd one...hope this tip will help someone.

12/12/2024
A simple changing of the PCB which is now at the price of £245 including vat...but it was a tricky situation where the p...
28/08/2024

A simple changing of the PCB which is now at the price of £245 including vat...but it was a tricky situation where the pcb comes on after few minutes but the display goes totally blank once the sequence start and the fan comes in action.
Tip: Isolate the power.
Remove pump and fan wire.
Turn the boiler on.
If the pcb stays on.
Isolate the power.
Install the pump wire back.
If it stays on.
Your pump is fine.
Now isolate again.
Put the fan wire back.
If the sequence start and the screen goes blank...without showing any fault code
It is the PCB then.
Remember : When i install the pump wire back but not the fan the pcb was showing fan fault.
But after 11 years the few things in the PCB was not strong enough to take the load and when the fan need the power it was not able to provide...hence going as there is no power to the boiler.
After few minutes when the faulty components in the pcb cools off...the boiler was back on power.

Hi.Came across this today where the tenant is complaining that the hot water is not coming on but the heating is fine.Di...
21/08/2024

Hi.
Came across this today where the tenant is complaining that the hot water is not coming on but the heating is fine.
Diagnose and found that the red light on the
flow sensor was cutting down when the demand for the hot water is on.
When tey to removed this flow regulator the bottom bit was broken and was stuck.
Tried to use my tool to pull the remaining part out but no success.
Then eventually have to bring the THE TITAN in to suck it out.
The customer is now a happy 🐇.

This jointing compound at the isolation valve causing less pressure at gas valve plus combustion readings all over the p...
27/06/2024

This jointing compound at the isolation valve causing less pressure at gas valve plus combustion readings all over the place.
Customer was told for a new gas run.
All sorted.
Another jolly and happy customer






Can someone count....how many
18/03/2024

Can someone count....how many

Although there was no sign of leaks and any condensation around...even the CO was spot on....this visual check on a 5 ye...
30/08/2022

Although there was no sign of leaks and any condensation around...even the CO was spot on....this visual check on a 5 years old Ideal combi 24.....turns out to be a change of full heat exchanger after getting confirmation Email from ideal technical team by sending them the picture.
Saved a hell lot of trouble to the customer on a Annual check.
Imagine if it crack and all that hot water in there 🤯.
Isolate electricity
Isolate the gas to the boiler.
Drain the boiler.
Good practice always help you and others.







16/02/2022

A great thank you to Chirag panchal..... Cputilities....to show while working how to check just the simple thing and repair them without replacing and causing a big job to yourself plus a big bill to the customer.
If you are not following ....you should and must do...just watching his videos are so knowledgeable and learning curve....that you will see how they workout when you are out on a job and come across the problem he shows you to solve.

16/12/2021

Have to be very much in details of checking when ever i come across a Worcester....couple of year old boiler having a split heatexchanger...not from the combustion side but from the main water heating chamber side.
Always remember that these particular type heatexchanger are worst made and still in production.
If come across these one you have to check them properly otherwise you have to be questionable if something goes wrong anytime soon after your gas certificate.
On every occasion if i found these heat exchanger showing sign of hard scale....i have contacted worcester...gave them the serial number and to whom the boiler is registered and get it replaced...only if the boiler is less than 10 years old or if i cannot obtain the details of the owner or the benchmark...it is a ID situation.
Just writing all these bcoz the first time it was quiet a time consuming situation for me.
I learnt...so that's why I am sharing this with all my new and fresh gas engineers who recently have jump in this buisness or not aware what to do if they come across this situation.
Always use a gas safe registered engineer to touch.....repair or install your boiler.