This LPG regulator went rogue, no Over Pressure Shut Off so high pressure into property, luckily boiler locked out but h...
09/04/2026

This LPG regulator went rogue, no Over Pressure Shut Off so high pressure into property, luckily boiler locked out but hob had huge flames.
Blew my unicorn tears fluid out of my water gauge and made my digital gauge go over limit so I don’t know what the actual pipe pressure was.
New regulator installed with OPSO protection.
It’s as high as I can fit it on the mounting post, the old one was installed below cylinder outlet so may have oiled up the reg and made it go faulty.
πŸ‘¨πŸ»β€πŸ”§πŸ”₯

Finished this one off today, existing Glowworm Ultimate sprung a leak from the main heat exchanger so rather than repair...
07/04/2026

Finished this one off today, existing Glowworm Ultimate sprung a leak from the main heat exchanger so rather than repair the homeowner requested this boiler as a replacement.
Vaillant Ecotec Pro 30KW πŸ”₯
Vaillant VRT 350F programmable room thermostat πŸ”₯
I had to relocate most of the pipework and it is in a bit of a tight space next to the consumer unit.
New condense pipework installed as the old one just terminated through the wall.
These are solid boilers and will last way beyond its warranty period.
I hope these are continued to be manufactured…

Well!! Me and my mate attacked this today, I’m meant to be off and getting ready for holiday, I’ve got two hours to get ...
10/03/2026

Well!! Me and my mate attacked this today, I’m meant to be off and getting ready for holiday, I’ve got two hours to get packed now 🀣
It needed two of us to pull the trac pipe through.
I was utterly shocked to see the state of the gas Pipework as it passed into the property, no sleeve and absolutely rotten. It was leaking into the cavity wall.
28mm trac pipe installed below floor and pipework altered to suit.
All back on and working.
Knackered 🀣
Cheers Clive Johnson, absolute legend today.
Trench is sand filled ready for builder to make good.

Lots going on at the moment!Went to do a boiler service the other day and as soon as I got to the door could smell gas.W...
06/03/2026

Lots going on at the moment!
Went to do a boiler service the other day and as soon as I got to the door could smell gas.
Whilst inside the smell was apparent, I had serviced this boiler for 3 years so this was a bit of a surprise.
Tightness test gas installation- fail.
Removed some flooring to access pipework- black iron- can not find escape.
Capped off pipework below floor to leave a 2mtr section where pipe enters property- still fail- even worse to be honest.
Back outside and I can smell gas.
Meter in garage, goes underground, under a concrete path and then into property.
Went back today with my mate, gunned up the concrete path where the pipe is to expose- 6 inch thick!!
Had to go and hire a bigger breaker and that struggled.
Now have the iron exposed, it’s directly laid in soil with no protection.
Next job is to go back and do a full gas pipe replacement with Tracpipe.
Now, I am away next week so I have had to sub this to my friend to get my customer back on gas.
Been lots of organising on this job and only started with a simple visit for boiler service.
Some of the iron pipe I pulled out was very poorly installed, some fittings are only threaded on a few threads.
It’s done well to last this long as would have been installed early 70s.
πŸ‘¨πŸ»β€πŸ”§πŸ”₯ πŸ”§

03/03/2026

Just a heads up guys, I’m away on holiday next week and I will not be contactable as on a holiday SIM card. I’m trying my best this week to clear down pre booked jobs!
πŸ™‚πŸ‘¨πŸ»β€πŸ”§πŸ”₯🍺 πŸ₯³

24/02/2026

Small works back on today, finished the Chinese takeaway job πŸ™
4 landlords gas safety checks completed with a few remedials to note πŸ‘¨πŸ»β€πŸ”§
Went to a gas hob that some numpty has installed on LPG park home without conversion so flames yellow and lifting off πŸ€¦β€β™‚οΈ
Conversion injectors fitted and flame height set- no installer details- same old…
Be careful who does your gas work and check gas safe register to see if they are actually qualified.
Finished off the day resetting a boiler in another park home after a bottle change and notes on incorrect regulator placement and hose age. πŸ‘¨πŸ»β€πŸ”§πŸ”₯

Been very busy at the moment and realise I have not posted much. Had a real pain of a job yesterday which saw me pack my...
24/02/2026

Been very busy at the moment and realise I have not posted much. Had a real pain of a job yesterday which saw me pack my van up at 7pm. Went back this morning to flush and load up waste materials into van. Difficult job in every way, no local parking,existing boiler very heavy- 60kg, lots of pipework alteration and a timescale for business to be back in operation as soon as possible! Fitbit tells me I did 6,723 calories burnt and 9.8km walked.
Took three of us to get it off the wall and released from pipework involving the customer 🀣
Also found out that it was only hung on one wall support but still gave us a fight.
Existing balanced flue gutted to keep the external trim and pro vent brick repair. πŸ”§
75mm celotex to internal and external section of old flue terminal πŸ”§
Hygienic plastic panel installed inside to hide wall damage- commercial kitchen so wipe clean πŸ”§
External altered to suit new flue and plastic clad πŸ”§
Alters all pipework to suit- Glowworm micracom used to keep the cost down and to make it even more difficult this has the heating return in the wrong position. Boxing below boiler very shallow so had to try and make the return filter fit.
EPH CP4 wireless programmable thermostat fitted πŸ”₯
Chinese takeaway back on with hot water and heating and I am now in possession of a very greasy old boiler and a knackered body πŸ˜†πŸ˜­
Vaillant VCW balanced flue boiler out- 1987 made. Who knows what the original boiler was as the external wall had previous repair same as internal but that would be pre 87.
Took some tekkers this one…

Completed! Vaillant Ecotec plus out and Worcester 4000 in place.Internal pipework insulated. πŸ”₯ External condense upgrade...
05/02/2026

Completed!
Vaillant Ecotec plus out and Worcester 4000 in place.
Internal pipework insulated. πŸ”₯
External condense upgraded in size πŸ”₯
Worcester care pack: filter, chemicals and wireless programmable room thermostat. πŸ”₯
This is in a bedroom and fortunately these are very quiet running boilers.
I do really like these, boiler of choice now.
Very well put together, nice colour screen and actually looks nice.

Starting a boiler change at mid day on a Friday wasn’t my best move but I have had to dodge the weather on this one. Ver...
25/01/2026

Starting a boiler change at mid day on a Friday wasn’t my best move but I have had to dodge the weather on this one. Vertical flue on a felt roof property, I did not enjoy getting on the roof! I’ve made this one happen so the family can have hot water and heating back on, original Ecomax boiler was very poorly.
Finished yesterday afternoon with lots of rushing around flushing and replaced 11 x thermostatic radiator valves.
Very tired today!
10 years manufacturers warranty πŸ”₯
EPH controls as standard πŸ”₯
Very difficult this one!
Straw walls here as well.

19/01/2026

Busy day today on repairs! Got back to this one that I shut down on Friday due to LPG gas escape.
Now had access below mobile home, leak repaired, Morco boiler serviced- fan replaced. The heat exchanger was filthy on this and it had blocked the condense trap.
All left working πŸ‘¨πŸ»β€πŸ”§πŸ”₯

Comfort at home is essential, and expert gas solutions can make all the difference. Elevate your living space by explori...
09/01/2026

Comfort at home is essential, and expert gas solutions can make all the difference. Elevate your living space by exploring our comprehensive services online at sandhamgasservices.co.uk.

Address

Sandown
PO369DS

Opening Hours

Monday 8am - 5pm
Tuesday 8am - 5pm
Wednesday 8am - 5pm
Thursday 8am - 5pm
Friday 8am - 5pm

Telephone

+447810021074

Alerts

Be the first to know and let us send you an email when Sandham Gas Services posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Share