Leaking towel radiator replaced, as near like for like swap as possible.3 rooms not heating up adequately, single panel ...
14/04/2026

Leaking towel radiator replaced, as near like for like swap as possible.

3 rooms not heating up adequately, single panel radiators replaced with doubles.

Heating on constant traced to faulty zone valve.  Replaced actuator to rectify.F75 error on Vaillant.  Blocked pressure ...
14/04/2026

Heating on constant traced to faulty zone valve. Replaced actuator to rectify.

F75 error on Vaillant. Blocked pressure sensor, replaced.

No power to boiler, fuses checked. Faulty PCB replaced.

Called to emergency leak, old plastic scale reducer split. Cut out and fitted temporary link to restore water to property.

Leak in boiler during a service traced to leaking automatic air vent, replaced.

Previous ongoing leak corroded pipework under sink. Cut out redundant pipework and replaced the rest. Taps also upgraded to deck mixer.

Badly scaled and leaking basin taps replaced

Boiler swap completed.  Alpha ripped out and replaced with ideal logic combi due to solar thermal at property.  Fitted w...
14/04/2026

Boiler swap completed. Alpha ripped out and replaced with ideal logic combi due to solar thermal at property. Fitted with sigma UB filter, scale reducer and shock arrestor. Controls upgraded to neomitis with smart optimisation.

18/12/2025

Closed till the New Year. Have a good Christmas. 

Some jobs from the last few weeks.  Feel free to message for any boiler/heating enquiries.  Minor plumbing work also und...
09/11/2025

Some jobs from the last few weeks. Feel free to message for any boiler/heating enquiries. Minor plumbing work also undertaken.

No heating at property traced to a damaged thermostat. Upgraded to wireless neomitis.

Intermittent heating traced to leaking/damaged zone valves

Poor dhw, replaced faulty divertor cartridge.

Faulty bath/shower mixer. Sourced as close match as could and fitted.

New Baxi 836 boiler fitted in loft with Adey pro2 filter, scale reducer, hive controls and a system flush.

Couple of recent jobs.  Feel free to message for any boiler enquiries.  Minor plumbing works also undertaken Banging boi...
30/09/2025

Couple of recent jobs. Feel free to message for any boiler enquiries. Minor plumbing works also undertaken

Banging boiler traced to faulty erp pump. Replaced.

Replacement shower fitted fitted with pump.

Like for like combi swap done the other day.  Sigma UB filter fitted to keep things as tight as possible in cupboard.Con...
30/09/2025

Like for like combi swap done the other day. Sigma UB filter fitted to keep things as tight as possible in cupboard.
Controls upgraded to user friendly neomitis.
Scale reduce and shock arrestor fitted under kitchen sink out of sight.

A few recent jobs.  Feel free to message for any boiler service/repair enquiries.  Minor plumbing works also undertaken....
15/09/2025

A few recent jobs. Feel free to message for any boiler service/repair enquiries. Minor plumbing works also undertaken.

No hot water at property. Traced to faulty 3-way valve. Replaced faulty motor 👍🏻

Leaking boiler - replaced damaged condense hose

Corroded internal gas pipe from a previous leak picked up on a service - part replaced

Like for like boiler swap.
Fitted with system filter, magnetic scale reduce, shock arrestor and wireless controls

Toilet constantly filling cistern, replaced faulty fill valve

Few recent jobs.  Feel free to message for any boiler service/repair enquiries.  Minor plumbing works also undertaken.Fa...
07/08/2025

Few recent jobs. Feel free to message for any boiler service/repair enquiries. Minor plumbing works also undertaken.

Faulty analogue room stat swapped out for new digital wireless neomitis.

Faulty heating zone valves swapped out. Full drain down, refilled and tested.

Leaking kitchen deck mixer tap replaced.

Faulty thermostat upgraded to wireless neomitis with smart optimisation.Feel free to message for boiler enquiries.  Mino...
03/08/2025

Faulty thermostat upgraded to wireless neomitis with smart optimisation.
Feel free to message for boiler enquiries. Minor plumbing works also undertaken

Leak under boiler traced to faulty soldered joint.  Pipework cut out and replaced
27/07/2025

Leak under boiler traced to faulty soldered joint. Pipework cut out and replaced

Recent combi swap.  Like for like swap due to restricted pipework.  Sigma UB filter used to keep everything tight to boi...
27/07/2025

Recent combi swap. Like for like swap due to restricted pipework. Sigma UB filter used to keep everything tight to boiler. Danfoss controls upgraded to Neomitis with smart optimisation