04/08/2026
Customer wanted their old hose bib replaced.
The original install was done wrong—mounted straight into the siding with no proper backing.
Installed a mounting block, replaced the hose bib, and sealed it properly. The mounting block also allowed the new frost-proof bib to be set at the correct ~5° downward angle for proper drainage and freeze protection.
Details matter on installs like this.