We recently completed a commercial sized pump replacement for an old wedding venue 5hp 35gpm. Upon initial inspection, we evaluated the well pump wire was broke and needed to be replaced or repaired with possible other issues as well. As we removed the pump to fix the issue, we noticed many scuff marks on the pipe and wire from not having a pipe centralizers. Turns out the wire was worn through in 3 places and burnt in 2 of them. We disconnected the pump and tested it also. Fried motor. Customer opted for a complete new motor and wet end assembly along with double jacketed wire and centralizers every 40ft. We began to install all the new products but we only could get to 80ft from surface level before our new pump got hung up on something. So we removed it and it had loads of scuffing on it. So we looked down the well and then we could see our new pump brought up what looked like wire. So he hooked it and pulled. Wound up being baling wire from and old cable tool rig. No luck we only got a 13ft section out. Went be back with a well camera. Pushed the cable down the hole 30ft, hooked it, twisted it around and pulled. Next thing you know. 260ft of cable comes out of the hole. Put the new pump in and all is good! We are extremely happy to have been able to save this customer upwards of 20-30 thousand dollars on a new well or continually replacing broken wires and bad pumps in the future!