Timdestasiohvac

Timdestasiohvac Training the future of HVAC technicians.

If you're a  member, don't miss my article in the June newsletter! It's a summary of my upcoming presentation im Septemb...
06/02/2026

If you're a member, don't miss my article in the June newsletter! It's a summary of my upcoming presentation im September at the NCI Summit.

(ACCA) Manual T matters. A client of mine asked how the Fittes floor registers compare to the Truaire register I normall...
05/28/2026

(ACCA) Manual T matters. A client of mine asked how the Fittes floor registers compare to the Truaire register I normally spec.

The max pressure drop across a register or grille that we usually design for is .03". A decently engineered 4X10 usually can handle up to 120 CFM (watch your throw and spread). The Fittes 4x10 already exceeds .03" at 45 CFM. In fact to get 120 CFM, you'd have to step up to a 8X14.5.

For small rooms, you may not need to significantly increase the register size . But for large rooms and open areas where throw, spread, noise and volume matter, these decisions have to be made BEFORE the HVAC is roughed in and boots installed.

05/25/2026

Faster, better, stronger, free'er

 now offers in- home temporary assessments. I've switched over to using this instead of the other 2 devices I had been u...
05/24/2026

now offers in- home temporary assessments. I've switched over to using this instead of the other 2 devices I had been using in order to gather the data I want. The Room Monitor gathers temperature, humidity, TVOC's Particulate Matter 2.5 and Carbon Dioxide. It only takes a couple minutes to plug in and deploy and now it works off bluetooth so you don't need the customer's wifi info any more. What do you see here that you would want to remedy and how would you propose fixing it?

05/22/2026

Stay tuned for the proposal to fix this- it's not as black and white as it seems.

05/21/2026

Pressure pan by demo

05/18/2026

Using my 60 point HVAC Assessment process.

Duct leakage test training on Oak Island with thesqe guys this morning.
05/14/2026

Duct leakage test training on Oak Island with thesqe guys this morning.

05/13/2026

Check out the Summit Sep 1-3 2026. I will be giving the condensed version of my 3-hour indoor air quality class which explains the hidden dangers behind a lot of air purifier technology as well as the four pillars of indoor air quality that we should be basing a recommendations off of.